TECHNICAL DATAExternal dimensions
Internarl dimensions
Lenght6055mm
5815mm
Width2435mm
2195mm
Height3100mm
2550mm
Floor maximum load400 kg/m²

Weight
2900kg
Exteriot colour

Anthracite grey - RAL7016
Colour system with high weather and aging resistance, suitable for urban and industrial environments.
Wall panels: 25 μm coating thickness
Frame: 75-120 μm coating thickness

Interior  White - RAL9010
Wall panels - covered with white painted steel sheet 0.50mm
Windows
3 kordsed klaasid gaasitäidisega - Ug = 0,7W/m²K
Standard windowWith manually opening external roller shutter
Double windowExternal aluminum blinds that can be opened with a remote control
Full glazing External aluminum blinds that can be opened with a remote control


Electric fittingsExternal input 400V/32A/5-pin
2kW electric radiator

Specification: hidden cabling Protection class IP20
 Socket according to national standards

Rainwater systemRoof structure with internal roof drain DN75



Wind resistancevref = 27.5 m/s, (100 km/h) terrain category III
At wind speeds over 27.5 m/s (100 km/h), additional fixing of cabins must be performed (anchoring, screwing, etc.).
Such measurements must be calculated by recognized professionals, taking into account local standards and conditions.
Snow load250kg/m²
Insulation:

RoofPU + MW / 80+120mm0.16 W/m²K
Wall panelPIR / 110mm0.20 W/m²K
FloorPIR + MW / 110+50mm0.14 W/m²K

Interior wallsMW / 60mm



Fire resistance:

Standard equipment
Fire resistance class of components according to standard EN 13501-2
Support structureR30
Roof structureREI30
Wall panelsEI30
Checked:Classification Report according to EN 13501-2, accredited institute IBS Linz